IVAC 572 MANUAL PDF

IVAC 572 MANUAL PDF

Before you When calculating rates.g. Quick Start-Up Guide Setting up an infusion for the Ivac Rate Calculation ml to be infused in 2 hours 30 minutes. The IVAC® Volumetric Pump automatically regulates the infusion rate of intravenous solutions. Users are advised to read, to understand this manual and to be thoroughly familiar with the Pump prior to Tel: (27) (0) interferon α-2α, , , , , , , interferon α-2b, , , , , IVAC, ixabepilone, –,, ,, , ixazomib, .

Author: Vishicage Kazragrel
Country: Botswana
Language: English (Spanish)
Genre: Love
Published (Last): 16 February 2015
Pages: 175
PDF File Size: 11.71 Mb
ePub File Size: 18.52 Mb
ISBN: 412-1-25049-930-8
Downloads: 85996
Price: Free* [*Free Regsitration Required]
Uploader: Vuzahn

Siemens SC Ventilator with Bracket.

IVAC® PCAM® Syringe Pump |

Should false alarm conditions be encountered, either remove the source of the interference or regulate the infusion by another appropriate means. The following curves show typical performance of the system in two ways: The PCA button will provide feed-back on all, or just good demands. Remove the handset inlet assembly from the lower case. Note 2—These guidelines may not apply in all situations.

Enter the access code Ensure that the header is pushed down onto the board and that the pins are not bent during the fitting of the header.

Note 4—CareFusion recommends using signal cables of less than 3 metres in length and this requirement is applicable only if signal cables are 3 metres or more in length. O n the 752 menu, select Capture Text.

Declutch plunger holder and move to the right. The two shorter flexi circuit fixing screws are fitted nearest to the motor. If the self-adhesive pad item D is not present, fit the pad to the top of the transformer then fold the ribbon cable firmly as shown below.

  ARISTOTEL POETICA PDF

Note 2—Compliance levels raised by EN R emove the encoder flag and opto mount from the assembly. Enter text from picture: Remove the three retaining grub screws from the lock seal body. To strip down each lower case sub assembly, follow the instructions in the relevant section of this chapter.

This signal is applied to a schmitt trigger then read via IC9. The hand set connector is a latching but non-locking connector. R emove the four screws securing the base plate to the underside of the lower case.

Remove the two screws securing the motor assembly to the mounting plate. Loading doses are not available. Consult other organizations that publish guidelines useful in developing facility protocols. Page 28 CareFusion Corporation or one of its subsidiaries. Remove the chassis plate, disconnecting flexi circuits as required.

Should the clinical situation require it, the indicator light can be disabled. A Excessive force will damage the plunger mechanism. The patient handset does not contain any latex. The supply operates to control the lamp current at about 5mA and operates over the full mains unregulated supply and internal battery voltages, fed via MVCC.

DRUG 1 is displayed. In normal operation if the watchdog fails the power is prevented from reaching the motor. Datex Ohmeda Tec 7 Sevoflurane x 2.

  KDL46HX800 MANUAL PDF

To reassemble the components into the new lower case, simply reverse the order of disassembly. Also use this language for communications and paperwork where possible.

IVAC® PCAM® Syringe Pump

Micro Medical Microlab Series Spirometer. Refer to the relevant DFU for the recommended routine maintenance period. These notes provide useful advice or information that may help to perform the task more effectively. Control PCB Contains the main processor module which provides the control functions for almost all aspects of the pump. Turn the pump ON. Remove the lock seal body, the lock sealing nut and washer from the assembly.

Fit item Manuxl – alarm cover label LB to decrease alarm volume if the alarm volume is still too loud at it’s lowest position. Plunger Detect The syringe plunger button position is detected using a slotted optical switch. Real-time Clock The real time clock chip, IC13, maintains time and date information. R Remove the screw and washer securing the potentiometer assembly then remove the potentiometer assembly.

To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.